TM 11-6625-2611-12
CHAPTER 4
OPERATOR/CREW MAINTENANCE INSTRUCTIONS
4-1. Tools and Equipment
The following test equipment is required for organiza-
tional maintenance:
a. Multimeter AN/USM-223.
b. Oscilloscope AN/USM-281A or oscilloscope
AN/USM-281C.
C. Tools. Tools required for organizational mainte-
nance are included in standard issue Tool Kit,
Electronic Equipment TK-105/G.
4-2. Lubrication
Lubrication of the test set is not required.
4-3. Preventive Maintenance Checks and
Services
To insure that Transponder Set AN/APM 305 A is al-
ways ready for operation, it must be inspected
systematically so that defects may be discovered and
corrected before they result in serious damage or
failure. The necessary preventive maintenance checks
and services to be performed are listed and described in
table 4-1. The step numbers indicate the sequence of
and minimum inspection required. Defects discovered
during operation of the unit will be noted for future
correction to be made as soon as operation has ceased.
Stop operation immediately if a deficiency is noted
during operation which would damage the equipment.
Sequence
No.
1
2
3
Item to be
Inspected
Exterior surfaces
Controls and indicators
Operation
Record all deficiencies together with the corrective ac-
tion taken on forms per TM 38-750. Instructions for
performing the required checks are identified as
periodic checks.
4-4. Preventive Maintenance
These checks and services are to maintain electronic
equipment in a combat serviceable condition; that is, in
good general (physical) condition and in good operating
condition. To assist operators in maintaining combat
serviceability, the charts indicate what to check, how to
perform the check and what action to take to correct a
faulty indication. The Reference column lists the illus-
tration, paragraph, or other manual that contains
detailed repair or replacement instructions. If the
defect cannot be remedied by performing the corrective
action indicated, a higher category of maintenance is
required.
4-5. Preventive Maintenance Checks and
Services Periods
Preventive maintenance checks and services for the
test set are required daily, weekly, and quarterly.
4-6. Daily Preventive Maintenance Checks
and Services
The following chart specifies checks and services that
must be accomplished daily.
Procedure
Clean exterior surfaces including test set panel as-
sembly.
During operation of test set, observe that each con-
trol and indicator functions properly. Mechani-
cal action of each knob, dial, and switch should
be smooth and
free
of external or internal bind-
ing. Tighten loose controls as required.
When operating test set, be alert for
any unusual
performance or condition.
Reference
Para 5-2
None
None
4-7. Weekly Preventive Maintenance
must be accomplished weekly or at least once each
Checks and Services
month if the test set is not used periodically.
The following chart specifies checks and services that
Sequence
No.
1
2
3
4
5
6
Item to be
Inspected
Completeness
Exterior items
Cables
Connectors
Handles, latches, and hinges
Metal surfaces
Procedure
POWER OFF lNSPECTION
See that equipment is complete.
Check for looseness of exterior items, such as con-
nectors, switches, and latches. Tighten all loose
mounting screws and nuts.
Check cables for breaks, cuts, kinks, fraying, and
broken connectors; replace defective cables.
Inspect connectors for snug fit and good contacts.
Check handles, Iatches, and hinges for looseness
and defects.
Check all exposed metal surfaces for rust and cor-
Reference
Para 1-12
None
None
Higher category maintenance required
Higher category maintenance required
Para 5-3