Directed Electronics 671XP Guía de instalación Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
12
©
2004
Directed Electronics, Inc.
Diagram for adding optional Directed dual stage sensor to GREEN wire (zone 4).
BLUE (-) Multiplex Input
Inputs shorter than 0.8 seconds will trigger the Warn Away® response, while inputs longer than 0.8
seconds will trigger full alarm sequence and report Zone 2.
RED (+) 12V Constant and BLACK (-) Ground
Do not use these for anything besides the plug-in shock sensor.
NOTE: If adding additonal sensor(s), connect the power and ground of the additional
sensor(s) to the power and ground at the 12-pin harness.
504D
508D
BLUE
GREEN
GREEN
BLUE
Shock Sensor
Field Disturbance Sensor
Plug to Control Module