14 VAC D300 PSS EVE0105 A-(en)
&
"
ADDITIONAL EQUIPMENT built into basic device
versions HART, PROFIBUS-PA or FOUNDATION Fieldbus H1 with ATEX approval
Additional Inputs / Outputs:
Two Binary inputs - Code BI
(Options for AI 638 per EC- Certificate of Conformity
PTB 00 ATEX 2128)
Two independent binary inputs, supplied with the basic
device, for connection of external switches.
A connected switch is loaded with 3.5 V, 150 µA.
The binary inputs can be used for diagnostics or also
configurable for the control functions:
Switch 1 Switch 2 Actuator control function
close close normal operation
open close go to stop at 0 %
close open go to stop at 100 %
open open hold last position
KlemmenfürEB1.........A:13+
B: 14–
EB2.........C:15+
D: 16–
One module “Additional inputs / outputs” 8 can be plugged
on main electronics 40 :
Position feedback or
2 Binary outputs or
2 Binary intputs
Electrical Classification hereto:
(Electronics family AI 638 per EC- Certificate of Conformity
PTB 00 ATEX 2128)
see Certificate of Conformity EX EVE0105 A
TypeAI638B...........II2GEExiaIICT6
Types of protection and temperature classes as basic device.
To this electric circuit only passive electric circuits galva-
nically separated from earth may be attached.
The electric circuit has the following maximum values:
Uo= 7.88 V, Io= 11.4 mA, Po= 23 mW
Characteristic is linear
For the maximum values of outer inductances and capa-
cities Lo and Co refer to the following table (Li and Ci
included):
IIC IIB
Lo [mH] Co [µF] Lo [mH] Co [µF]
100 0.72 100 3.9
10 1.1 10 5.5
11.618.7
0.1 2.7 0.1 15
0.01 4.7 0.01 27
The electric circuits of "2 binary inputs" are galvanically
connected with all other circuits but separated from earth.
Type of protection FM “intrinsic safety”
ClassI,Div.1,GroupsA,B,C,D;
hazardous locations indoor and outdoor, NEMA Type 4X *)
Type of protection FM “non-incendive”
ClassI,Div.2,GroupsA,B,C,D,F,G;
hazardous locations indoor and outdoor, NEMA Type 4X
Type of protection CSA “intrinsic safety”
ClassI,Div.1,GroupsA,B,C,D;
hazardous locations indoor and outdoor, NEMA Type 4X *)
*) Under development