8 PSS EVE0105 A-(en)
FUNCTIONAL SPECIFICATIONS for basic device with
communication HART and ATEX approval
Signal Input
Two wire system
Reverse polarity protection feature
Signal range ............4to20mA
Operating range..........3.6to21.5mA
Input voltage ............DC12...36 V
1)
(unloaded)
Load ..................420Ohms,8.4Vat20mA
Communication signal .....HART,1200 Baud, FSK
(Frequency Shift Key)
modulated on 4 to 20 mA
0.5 Vpp at 1 kOhm load
Input impedance Zi........Z=320Ohms
for ac voltage 0.5 to 10 kHz with < 3 dB non-linearity
Cable capacity and inductance see HART standard
specifications. (e.g. C < 100 nF).
Impedance of other devices at the input (parallel or serial)
must be within HART spec.
Applications without communication require not to exceed
input capacitance parallel to the input not higher than 100 µF.
Start-uptime ............approx. 3 sec
Interruption time without power down:
withLCD+LED........typ.80ms
2)
Configuration
Local..................withlocalpushbuttons
Display.................fiveLEDsor
Multi-lingual Graphic LCD
The positioner in the version with LCD contains three
different menu languages.
Standard menu languages:
- English - German
Freely selectable third language:
- French - Portuguese - Spanish
- Italian - Swedish - ...
(further menu languages on request)
The third menu language has to be selected and specified
At time of order, third default language is Spanish.
Language by means of the configuration software
PC20/PC50.
Software ...............PC20/IFDC by Invensys
Hardware...............Modem MOD991 for PC, IBM
compatible
Hand Held Terminal .......HT991
I/A Series System ........FBM215orFBM218
in combination with CP60
3)
Other control systems .....AMS, Siemens SIMATIC PDM
(ProcessDeviceManager)
1) On request we can specify higher voltage limits
2) Worst case conditions 4-20mA, with position feedback option, i/p-output
with max. current
Electrical classification hereto:
4) 5)
see Certificates of Conformity EX EVE0105 A
Type of protection "intrinsically safe"
TypeAI638GH..........II2GEExiaIIB/IIC,
II 2 G EEx ib IIB/IIC
Temperature classes
T4 with explosion protection code EA4
T4 / T6 with explosion protection code EAA
CertificateofConformity....PTB00ATEX2128
For use in hazardous areas in circuits certified as intrinsic-
ally safe with the following maximum values:
Input circuit:
Umax=30V,Imax=130mA,Pmax=0.9W
Li = negligible, Ci = 1.3 nF (5.3 nF to earth)
Ambient temperature ranges:
TemperatureclassT4: ....
-
40ºCto+80ºC(-40 to176ºF)
TemperatureclassT6: .... -40ºCto+55ºC(-40 to 131ºF)
Type of protection FM "intrinsic safety"
ClassI,Div.1,GroupsA,B,C,D;
hazardous locations indoor and outdoor, NEMA Type 4X *)
Type of protection FM "non-incendive"
ClassI,Div.2,GroupsA,B,C,D,F,G;
hazardous locations indoor and outdoor, NEMA Type 4X
Type of protection CSA "intrinsic safety" *)
ClassI,Div.1,GroupsA,B,C,D;
hazardous locations indoor and outdoor, NEMA Type 4X
*) Under development
3) Check CP for suitable ECBs
4) With appropriate order only
5) National requirements must be observed
VAC D300