GOSSEN Mueller & Weigert 11
Order Example:
Moving-Coil Ammeter, 72 x 72 mm, 40 ... 0 ... 40 A
Order No.: 3150P BD2 CC40
Front Dim. in mm
48 x 48 72 x 72 96 x 96 144 x 144
Type
DS 48 DS 72 DS 96 DS 144
Order No.
3100P 3150P 3200P 3250P
(in prep.)
Meas. Input Direct Current Connection Current
Zero Point left direct
−++++
center direct BD2 ++++
1 mA CB1 ++++
5 mA CB5 ++++
10 mA CB10 ++++
20 mA CB20 ++++
1 A/1.5 A/2.5 A/4 A CC1/1.5/2.5/4 ++++
6 A/10 A/15 A CC6/10/15 ++++
25 A CC25 + +++
40 A CC40 −+++
60 A CC60 −+++
10% pos. upper value direct
0.1 ... 0 ... 1 mA
BD3 CB1 ++++
2 ... 0 ... 20 mA
BD3 CB20 ++++
mech. suppressed direct
4 ... 20 mA
BD4 −++++
left at shunt resistor .../60 mV Current: ... A BD5 CG ... ++++
Current: ... kA BD5 CH ... ++++
center at shunt resistor .../60 mV Current: ... A BD6 CG ... ++++
Current: ... kA BD6 CH ... ++++
left at shunt resistor .../150 mV Current: ... A BD7 CG ... ++++
Current: ... kA BD7 CH ... ++++
center at shunt resistor .../150 mV Current: ... A BD8 CG ... ++++
Current: ... kA BD8 CH ... ++++
Meas. Input Direct Voltage Connection Voltage (upper range value)
Zero Point left
−++++
center BD2 ++++
10%
pos. upper value BD3 ++++
direct 10/40/100 V DC10/DC40/DC100 ++++
1 to 300
V (not 10/40/100 V) DC1 to DC300 ++++
400/500/600 V
DC400 to DC600
+
1)
+++
Scale Graduation
corresponds to measuring range
−++++
scale deviates from measuring range
GL ... ++++
without scale
GL95
++++
blank scale, lower and upper value markings, company logo, symbols
GL98 ++++
Scale Characteristics
proportional to current
−++++
per curve
SD999 ... ++++
Applications
standard
−++++
conditionally tropic-proof, climatic category 3
LB4 ++++
Resistance to Vibration /
standard
−++++
Marine Applications
vibration resistance: 2.5 g, shock resistance: 30 g
LN56 ++++
marine applications, German Lloyds
LN8 ++++
Operating Voltage
standard
−++++
600 V (600 V CAT lll)
LS9
+
2)
3)
3)
3)
Bezel
dull black
−++++
dull grey, RAL 7037
MA11 ++++
Glass Faceplate
standard
−++++
anti-glare
MG1 ++++
anti-glare, with red adjustable set pointer
MG98 ++++
Housing and Fasteners
4)
standard
−++++
sheet metal housing with type S screw clamp
ML7
++
sheet metal housing with type B screw clamp
ML8
++
polycarbonate housing with 2 leaf springs
ML9 +++
polycarbonate housing with Subklew fasteners
ML10 +++
Identification none −++++
at rear: ............ MZ998 ... ++++
Scale Inscription none −++++
(Latin lettering)
18 characters, 1 line: .......... (not possible for 2
nd
inscription)
SM903 ... +
−−−
22 characters, 1 line: ..........
SM902 ...
+++
37 characters, 2 lines: 1
st
line (15 characters) .., 2
nd
line (22 char.) ..
SM911 ...
+++
Additional Numbering none −++++
2
nd
set of numberings, black: ... SK982 ... ++++
2
nd
set of numberings, red (RAL 2002): ... SK983 ... ++++
Red Marker (RAL 2002) none −++++
red marker at: ... ST981 ... ++++
Order Number Instructions:
See page 13 for operating position and degree of protection options.
1) Operating voltage: 600 V (600 V CAT III), only in combination with order no. LS9
2) Not possible for direct connection >6 A.
3) Standard model
4) See page 13 for additional options.
Select one model each for order numbers with the same sequence of letters.
No add. entries are required for std. models (identified with bold typeface and “in the order no. column).
An entry with “....” in the order no. column means that order number must be supplemented with text.
+
+
Square Panel Meters
for Direct Current or Direct Voltage
Order Information
Code: B0