24 GOSSEN Mueller & Weigert
Order Example:
Active Power Meter for 3-Wire System with Unbalanced Load,
100/5 A Transformer Ratio, 400 V Nominal Voltage, Measuring Range:
0 ... 60 kW
Order No.: 3200D AB4 BE11 CG100 IL340 NB: 0 ... 60 kW
Front Dim. in mm 96 x 96 144 x 144
Type LM 96 LM 144
Order no.
3200D 3250D
(in preparation)
System Type / Power Type Voltage Path Terminal
2-Wire System
Active Power, Single Phase AC AB1
++
at transformer sec.: 100 V primary voltage: ... V BF12 DG ... ++
primary voltage: ... kV BF12 DH ... ++
at transformer sec.: 110 V primary voltage: ... V BF15 DG ... ++
primary voltage: ... kV BF15 DH ... ++
direct, 220 VAC IL322 ++
direct, 230 VAC IL323 ++
direct, 240 VAC IL324 ++
Reactive Power, Single Phase AC AB11 ++
direct, 220 VAC IL322 ++
direct, 230 VAC IL323 ++
direct, 240 VAC IL324 ++
3-Wire System
Active Power, 3-Wire, Balanced Load AB2
++
Reactive Power, 3-Wire, Balanced Load AB12 ++
Active Power, 3-Wire, Unbalanced Load AB4 ++
Reactive Power, 3-Wire, Unbalanced Load AB14 ++
at transformer sec.: 100 V primary voltage: ... V BF12 DG ... ++
primary voltage: ... kV BF12 DH ... ++
at transformer sec.: 110 V primary voltage: ... V BF15 DG ... ++
primary voltage: ... kV BF15 DH ... ++
direct, 380 VAC IL338 ++
direct, 400 VAC IL340 ++
direct, 415 VAC IL661 ++
direct, 440 VAC IL344 ++
direct, 500 VAC IL350 ++
4-Wire System
Active Power, 4-Wire, Balanced Load AB5
++
Reactive Power, 4-Wire, Balanced Load AB15 ++
Active Power, 4-Wire, Unbalanced Load AB6 ++
Reactive Power, 4-Wire, Unbalanced Load AB16 ++
at transformer sec.: 100 V primary voltage: ... V BF12 DG ... ++
primary voltage: ... kV BF12 DH ... ++
at transformer sec.: 110 V primary voltage: ... V BF15 DG ... ++
primary voltage: ... kV BF15 DH ... ++
direct, 220/380 VAC IL718 ++
direct, 230/400 VAC IL723 ++
direct, 240/415 VAC IL721 ++
direct, 254/440 VAC IL722 ++
direct, 277/480 VAC IL724 ++
Current Path Terminal at transformer sec.: 1 A primary current: ... A BE10 CG ... ++
primary current: ... kA BE10 CH ... ++
at transformer sec.: 5 A primary current: ... A BE11 CG ... ++
primary current: ... kA BE11 CH ... ++
Zero Point left −−− ++
center BC2 −− ++
10% of positive upper value BC6 −− ++
Upper Measuring Range Value (adjustable from 0.5 to 1.2 times apparent power) NB ... −− ++
Order Number Instructions:
Select one model each for order numbers with the same sequence of letters.
No additional entries are required for standard models (identified with bold typeface and “” in the order no. column).
An entry with “....” in the order no. column means that the order number must be supplemented with written text.
+
+
+
Square Panel Meters
for Active Power or Reactive Power
Order Information
Code: B0