Directed Electronics 3200HS Manual de usuario Pagina 17

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 76
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 16
GOSSEN Mueller & Weigert 17
Order Example:
Bimetal Ammeter, 96 x 96 mm, 100/5 A Transformer Ratio, Response Time 8 min.
Order No.: 3200M BG16 CG100 IB2
Front Dim. in mm 48 x 48 72 x 72 96 x 96
Type BM 48 BM 72 BM 96
Order no.
3100M 3150M 3200M
Connection Current
rated value 120% direct 1 A
BG10 CC1
+++
5 A BG10 CC5
+++
rated value 120% at transformer sec.: 1 A primary current: ... A BG 15 CG ...
+++
primary current: ... kA BG 15 CH ...
+++
at transformer sec.: 5 A primary current: ... A BG 16 CG ...
+++
primary current: ... kA BG 16 CH ...
+++
Scale Graduation corresponds to measuring range
+++
without scale GL95 +++
blank scale, lower and upper value markings, company logo, symbols GL98
+++
Position of Use
standard
−+++
0 ... 45 degrees from horizontal (bonded glass faceplate)
LA11 +++
46 ... 89 degrees from horizontal (bonded glass faceplate)
LA12 +++
91 ... 135 degrees from horizontal
LA13 +++
Response Time 15 min.
+++
8 min. IB2
+++
Bezel dull black
+++
dull grey, RAL 7037 MA11
+++
Glass Faceplate standard
+++
anti-glare MG1
+++
Housing and Fasteners standard
+++
sheet metal housing with type S screw clamp ML7
++
sheet metal housing with type B screw clamp ML8
++
polycarbonate housing with 2 leaf springs ML9
+++
polycarbonate housing with Subklew fasteners ML10
+++
polycarbonate housing with mount for H&B Unibloc grid ML12
+
1)
1)
polycarbonate housing for manual grid, no fasteners ML5
+
1)
1)
Identification none
++
at rear: ............ MZ998 ...
+++
Constants Display none
+++
display: 1-1.5-2-2.5-3-4-5-6-7.5-8-10 (for standard faceplate only) PK5
+
Scale Inscription none
+++
(Latin lettering) 18 characters, 1 line: .......... (not possible for 2
nd
inscription) SM903 ...
+
−−
22 characters, 1 line: .......... SM902 ...
++
37 characters, 2 lines: 1
st
line (15 char.): ..., 2
nd
line (22 char.): ... SM911 ...
+
+
Additional Numberings none
+++
2
nd
set of numberings, black: ... SK982 ...
+++
2
nd
set of numberings, red (RAL 2002): ... SK983 ...
+++
Red Marker (RAL 2002) none
+++
red marker at: ... ST981 ...
+++
1) Use order number ML9 for H&B Unibloc and manual grids.
Order Number Instructions:
Select one model each for order numbers with the same sequence of letters.
No additional entries are required for standard models (identified with bold typeface and “” in the order no. column).
An entry with “....” in the order no. column means that the order number must be supplemented with written text.
+
+
Square Panel Meters
for Alternating Current
Order Information
Code: B0
Vista de pagina 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 75 76

Comentarios a estos manuales