TEST REPORT
Page 22 of 33
Issue Date: 2
nd
March 2010.
SGS Serial Number:
AUT130731/4/GH/10.
Test Report
Date: 01-14-2010 Time: 12:38:06
AUT: 130731/1.
Company Name :
Directed Electronics Inc.
Equipment Tested :
Avital 3001L.
Serial Number :
Not marked.
Test Equipment used :
TESEQ Generators
Test Procedure Used :
ISO 7637 - 2.
General Conditions
Ambient Temperature :
19
Humidity :
48
Pressure :
986
Tested by :
G. Hann.
Signature :
Test Number 1
Test Name 12vp1.
Test Type MT 5511 Pulse 1
Sequence Repetition Count 5000
Test Status PASS. B.
U
S
U
A
0
t
3
t
2
t
1
V
t
t
d
90%
10%
-
+
EUT
Parameter Operation From To Step Size Fail Value
Pulse Voltage (Us) Static 75 V --- --- ---
Pulse Period (t1) Static 0.5 s --- --- ---
General Value
Rise Time (tr) 1 us
Output Resistance (Ri) 10 ohms
Pulse Width (td) 2 ms
t2 200 ms
Polarity/Coupling Negative Parallel
Battery
Battery State UPC/Time
Voltage 13.5 V
Current Limit 12.5 A
End of Test Voltage 13.5 V
Comments
During the test the Supply – flickered on/off, then returned to normal on completion of the test.