TEST REPORT
Page 25 of 33
Issue Date: 2
nd
March 2010.
SGS Serial Number:
AUT130731/4/GH/10.
Test Report
Date: 01-14-2010 Time: 14:53:05
AUT: 130731/1.
Company Name :
Directed Electronics Inc.
Equipment Tested :
Avital 3001L.
Serial Number :
Not marked.
Test Equipment used :
TESEQ Generators
Test Procedure Used :
ISO 7637 - 2.
General Conditions
Ambient Temperature :
19
Humidity :
48
Pressure :
986
Tested by :
G. Hann.
Signature :
Test Number 1
Test Name 12vp3a.
Test Type FT 5530 Pulse 3A
Sequence Repetition Hours 1
Test Status PASS. A.
U
S
U
A
0V
t
1
t
4
t
5
V
t
Parameter Operation From To Step Size Fail Value
Pulse Voltage (Us) Static 112 V --- --- ---
Pulse Freq (1/t1) Static 10 kHz --- --- ---
General Value
Rise Time (tr) 5 ns
Output Resistance (Ri) 50 ohms
Pulse Width (td) 100 ns
Burst Interval(t5) 0.09 s
Output Mode NORMAL
No Pulses (t4/t1)
Burst Duration (t4) 10 ms
Battery
Battery State On
Voltage 12 V
Current Limit 12 A
End of Test Voltage 12 V
Polarity
Polarity Negative
Comments
No changes recorded.