Directed Electronics Viper ESP 540 Guía de instalación Pagina 43

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 178
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 42
© 2009 Directed Electronics
37
Troubleshooting
Starter kill does not work:
z
Is the correct starter wire being interrupted? If the car starts when the
starter kill relay is completely disconnected, the wrong starter wire has
been cut and interrupted.
Is the yellow wire connected to “true” ignition? Make sure this wire
is connected to a wire that has power in the run and start positions.
The starter kill goes active 1 minute after arming the alarm. Make
sure you wait that time period before attempting to test.
The Valet switch does not work.
Is it plugged into the correct socket? See the Valet Switch section of
this guide.
Is the H1/9 YELLOW wire properly connected? See Primary
Harness (H1) Wire Connection Guide section of this guide.
If the mounting of the switch is a tight fit it can cause the switch not
to work properly. Make sure the hole size is drilled with a 5/16 drill
bit.
Status LED does not work.
Is the LED plugged into the small white port on the side of the con-
trol unit? See LED and Valet Switch section of this guide.