Feature menu 1
Factory default settings are shown in bold.
Feature steps 5 and 6 are related. Only if Auxiliary Output Enabled is
selected in step 5 can either Auxiliary Output or Delayed Accessory
Output be selected in step 6. Examples of this are where Auxiliary
Output is used to provide a momentary 800mSec pulse on the
RED/WHITE wire of the main harness. It may be used for opening the
trunk. (continued on next page.)
Feature
Step
Lock Button (one chirp)
Unlock Button (two chirps)
1
Active arming
Passive arming
2
Chirps ON
Chirps OFF
3
Door Trigger Error Chirp ON
Door Trigger Error Chirp OFF
4
Ignition-Controlled Domelight ON
Ignition-Controlled Domelight OFF
5
Panic Enabled (OEM upgrade)
Auxiliary Output Enabled (OEM upgrade)
6
Auxiliary Output
Delayed Accessory Output
7
Delayed Door Trigger
Instant Door Trigger
8
Sensor shunt zones 1, 2 & 4
All zones
9
Siren Duration–30 seconds
Siren Duration–60 seconds
10
Valet switch input: 1-pulse
Valet switch input: 2-5 pulses
11
Horn pulse honk duration 0.020
seconds (does not affect full trig-
ger pulse duration)
0.030, 0.040, 0.050 seconds