DE3
CIRCUIT BREAKERS
01/15
DE3-11
QO™ and QOU Miniature Circuit Breakers
QO™ Miniature Circuit Breakers
QO
™
Arc-F ault Circuit Breaker
QO arc-fault circuit breakers provide branch feeder
protection for series and parallel-type arcing as required by
the NEC and local code adoption, and comply with
UL1699.
QO Arc Fault Circuit Breakers
a
Circuit Breaker Type
Ampere
Rating
1P 120 Vac 1P 120 Vac
10 k AIR 22 k AIR
1 Space Required 1 Space Required
Cat. No. Cat. No.
Combination Arc-fault
Interrupter
15
A QO115CAFI QO115VHCAFI
20 A QO120CAFI QO120VHCAFI
QO-GFI
Qwik-Gard™ circuit breakers provide overload and short
circuit protection, combined with Class A ground fault
protection. Class A denotes a ground fault circuit
interrupter that will trip when a fault current to ground is 6
mA or more, for people protection. Do not connect to more
than 250 feet of load conductor for the total one-way run to
prevent nuisance tripping.
QO-GFI Circuit Breakers
Ampere Ratingc (A)
Qwik-Gard Circuit Breakers
With Ground Fault Circuit Interrupter
1P 120 Vac
2P Common Trip
120/240 V ac
10 k AIR 22 k AIR 10 k AIR
1 Space Required 1 Space Required 2 Spaces Required
Cat. No. Cat. No. Cat. No.
15 QO115GFI QO115VHGFI QO215GFI
20 QO120GFI QO120VHGFI QO220GFI
25 QO125GFI QO125VHGFI QO225GFI
30 QO130GFI QO130VHGFI QO230GFI
40 — — QO240GFI
50 — — QO250GFI
60 — — QO260GFId
QO-EPD
/EPE
QO-EPD/EPE circuit breakers provide overload and short
circuit protection combined with Class B ground fault
protection. They are designed to provide ground fault
protection of equipment at a 30 milliampere level (EPD) or
100 milliamp level (EPE). They are not designed to protect
people from electrical shock.
QO-EPD Circuit Breakers
Ampere Ratingc (A)
1P
120 V ac
2P Common Trip
120/240 V ac
3P Common Trip
240 Vac
10 k AIR 10 k AIR 10 k AIR
1 Space
Required
2 Spaces Required 3 Spaces Required
Cat. No. Cat. No. Cat. No. Cat. No.
15 QO115EPD QO215EPD QO315EPDe QO315EPEe
20 QO120EPD QO220EPD QO320EPDe QO320EPEe
25 QO125EPD QO225EPD — —
30 QO130EPD QO230EPD QO330EPDe QO330EPEe
40 — QO240EPD QO340EPDe QO340EPEe
50 — QO250EPD QO350EPDe QO350EPEe
60 — QO260EPDd — —
QO-SWN
Switch Neutral Common Trip 2008 NEC™ 514.11
QO-SWN C
ircuit Breakers
Ampere
Ratingc
2 Wire 120 Vac 3 Wire 120/240 V ac
10 k AIR 10 k AIR
2 Spaces Required 3 Spaces Required
Cat. No. Cat. No.
10 A QO210SWN —
15 A QO215SWN QO315SWN
20 A QO220SWN QO320SWN
25 A QO225SWN —
30 A QO230SWN QO330SWN
40 A QO240SWN QO340SWN
50 A QO250SWN QO350SWN
QO-HID
HID circuit breakers are for use on circuits feeding
fluorescent and high intensity discharge (HID) lighting
systems such as mercury vapor, metal halide, or high
pressure sodium. These circuit breakers are physically
interchangeable with QO circuit breakers.
QO-HID Circuit Breakers
Ampere
Ratingc
1P 120/240 Vac
2P Common Trip
120/240 V ac
3P Common Trip
240 Vac
10 k AIR 10 k AIR 10 k AIR
1 Space Required 2 Spaces Required 3 Spaces Required
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price
15 A QO115HIDb QO215HID QO315HID
20 A QO120HIDb QO220HID QO320HID
25 A QO125HID QO225HID QO325HID
30 A QO130HID QO230HID QO330HID
40 A QO140HID QO240HID —
50 A QO150HID QO250HID —
QO-K
Key operated QO circuit breakers are available in single-
pole construction and can be mounted in any single-pole
space which will accept a standard QO. These circuit
breakers can be turned ON or OFF or to RESET with a
special key (catalog number QOK10) included with the
circuit breaker. These circuit breakers are UL Listed and
available as shown in the table.
QO-K Circuit Breakers
120 Vac—10 k AIR (1 Space Required)
Ampere Rating c Cat. No.
10 A QO110K
15 A QO115K
20 A QO120K
30 A QO130K
QO-HM
High magnetic trip circuit breakers are recommended for
applications where
high initial inrush may occur and for
individual dimmer applications.
QO-HM Circuit Breakers
Ampere Ratingc
1P
Cat. No
120 V ac—10 k AIR
15 A QO115HMab
20 A QO120HMab
Non-automatic (Standard) Miniature Switches
Miniature non-automatic switches have the same physical
packaging as miniature circuit breakers, but open only
when the handle is switched to the OFF position.
Non-automatic switches provide no overcurrent protection
or short circuit protection. They must not be used on
systems that have an available fault current greater than
the values listed in the table.
Non-automatic switches are UL Listed per UL 1087 and
are CSA certified.
QO , 240 Vac 10 kA
Ampere
Rating
2P 3P
Cat. No. Cat. No.
60 A QO200 QO300
100 A QO2000 QO3000
a CSA/UL Listed as HACR type for use with air conditioning, heating and
refrigeration equipment having motor group combinations and marked
for use with HACR type circuit breakers.
b CSA/UL Listed
as SWD (switching duty) rated. Suitable for switching
120 Vac fluorescent lighting loads.
c 10–30 A
circuit breakers are suitable for use with 60° C or 75° C
conductors. 35–60 A circuit breakers are suitable for use with 75° C
conductors.
d Suitable only
for feeding 240 Vac and 208 Vac two-wire loads. Does not
contain load neutral connection.
e See note in Instruction Bulletin when using in an enclosure with a
QO403
or QON prefix.
Interrupting Ratings ....................................P
ageDE3-2
Accessories .........................................P
ageDE3-12
Dimensions .........................................P
ageDE3-54
Class 685, 690, 730, 912, 950 / Refer to Catalog 0730CT9801