DE3
CIRCUIT BREAKERS
01/15
DE3-43
PowerPact™ Circuit Breaker Accessories
Compression Lugs and Power Distribution Connectors (PDC)
J-Frame Compression Lugs
P-Frame Compression Lug Kit
R-Frame Compression Lug Kit
Compression Lug Kits for PowerPact™ Circuit Breakers
Description
Circuit
Breaker Type
Ampere
Rating
System Range
Mounting
Type
Dimension A
(in)
Max. Lugs per
Terminal
Cat. No.
Qty.
Per Kit
Compression Lug Kits for H-Frame and J-Frame Circuit Breakers
Aluminum
Compression
Lug Kits
H-frame
60 A 62AWGAlorCu
Unit
1.2 1 YA060HD 3
150 A 1/0–4/0 AWG Al or Cu 2.5 1 YA150HD 3
J-frame
150 A 1–3/0 AWG Al or Cu 1.2 1 YA150JD 3
250 A 3/0–350 kcmil Al or Cu 2.5 1 YA250J35 3
Copper
Compression
Lug Kits
H-frame
60 A 6–1/0 AWG Cu 1.0 1 CYA060HD 3
150 A 4–2/0 AWG Cu 1.2 1 CYA150HD 3
J-frame
150 A 6–1/0 AWG Cu 0.7 1 CYA150JD 3
250 A 2/0–300 kcmil Cu 1.1 1 CYA250J3
3
Compression Lug Kits for L-Frame Circuit Breakers
Aluminum
Compression
Lug Kits
L-frame
400 A 4-300 kcmil Al/Cu
Unit
1.2 1 YA400L31K3 3
600 A 4-300 kcmil Al/Cu 2.5 2 YA600L32K3 6
400 A 2/0-500 kcmil Al/Cu 1 YA400L51K3 3
600 A 2/0-500 kcmil Al/Cu 2 YA600L52K3 6
400 A
500-750 kcmil Al
500 kcmil Cu
1 YA400L71K3 3
400 A 4-300 kcmil Al/Cu 1 YA400L31K4 4
600 A 4-300 kcmil Al/Cu 2 YA600L32K4 8
400 A 2/0-500 kcmil Al/Cu 1 YA400L51K4 4
600 A 2/0-500 kcmil Al/Cu 1.2 2 YA600L52K4 8
400 A
500-750 kcmil Al
500 kcmil Cu
2.5 1 YA400L71K4 4
Copper
Compression
Lug Kits
L-frame
400 A 2/0-300 kcmil Cu
Unit
1.2 1 CYA400L31K3 3
600 A 2/0-300 kcmil Cu 2.5 2 CYA600L32K3 6
400 A 250-500 kcmil Cu 1 CYA400L51K3 3
600 A 250-500 kcmil Cu 2 CYA600L52K3 6
400 A 2/0-300 kcmil Cu 1 CYA400L31K4 4
600 A 2/0-300 kcmil Cu 2 CYA600L32K4 8
400 A 250-500 kcmil Cu 1 CYA400L51K4 4
600 A 250-500 kcmil Cu 2 CYA600L52K4
8
Compression Lug Kits for M-Frame, P-Frame, and R-Frame Circuit Breakers
Aluminum
Compression
Lug Kits
M-, P-framec
250 A 2/0-300 kcmil
Unit
3.7 2 YA250P3 1
300 A 4/0-500 kcmil 3.9 2 YA300P5 1
400 A 2/0-300 kcmil 4.3 2 YA400P3 2
400 A 500-750 kcmil 3.7 2 YA400P7 1
600 A 4/0-500 kcmil 3.9 2 YA600P5 2
800 A 500-750 kcmil 4.3 2 YA800P7 2
R-frameac
1200 A 2/0-300 kcmil
I-line
Unit
3.8 4 YA1200R3 4
1200 A 4/0-500 kcmil 4.0 4 YA1200R5 4
1200 A 500-750 kcmil 4.4 4 YA1200R7 4
2000 A 2/0-300 kcmil a 8 YA2000R3 2
2000 A 4/0-500 kcmil a 8 YA2000R5 2
2500 A 500-750 kcmil a 8b YA2500R7 2
Copper
Compression
Lug Kits
M-, P-framec
400 A 4/0-500 kcmil
Unit
3.3 2 CYA400P5 1
600 A 4/0-500 kcmil 3.3 2 CYA600P5 2
800 A 500-750 kcmil 3.6 2 CYA800P7 2
R-framec
1200 A 4/0-500 kcmil
I-Line
3.5 4 CYA1200R5 4
1200 A 500-750 kcmil 3.8 4 CYA1200R7 4
a All unit-mount R-frame circuit breakers require terminal pads for mounting lugs of any type. See page DE3-44.
b 9
lugs for 3000 A circuit breakers
c Not for use on I-Line™ circuit breakers unless wire bending space is adequate.
PDC6HD6
PDC6JD4
Power Distribution Connectors for H-Frame, J-Frame and L-Frame Circuit Breakers
Use with Circuit
Breaker Type
Circuit Breaker
Ampere Rating
Wires Per Terminal &
Wire Range
Dimension A (in.) Cat. No.
Qty.
Per Kit
HD, HG, HJ, HLd
15–150 (6) 14–6 AWG Cu 1.0 PDC6HD6 3
15–150 (3) 14–2 AWG Cu 1.2 PDC3HD2 3
JD, JG, JJ, JLd
150–250 (6) 14–4 AWG Cu 1.0 PDC6JD4 3
150–250 (2) 14–1 AWG and (1) 3–2/0 AWG Cu 1.5 PDC3JD20 3
LD, LG, LJ, LL
150–600 (3) 14–1 AWG and (2) 3–2/0 AWG 1.28f PDC5DG20L3 3
150–600 (12) 14–4 AWG 1.31f PDC12DG4L3 3
Crimp lug or PDC connectors
extension past end or circuit
breaker “A” See Table
Extremity
of
Molded Case
w/Mechanical
Lugs
“A” See Table
PDC12P4 PDC6P20
d OFF end only when OFF end is the load end.
Power Distribution Connectors for M-Frame and P-Frame Circuit Breakerse
Use for multiple load connections on one circuit breaker in place of standard
distribution block to save space and time.
• Use on load end of circuit breaker only
• Use in UL508 Industrial Control applications only.
• Use in UL1995/CSA C22.2 No. 236 heating and cooling equipment.
• For Cu wire only.
Ampere Rating
(Wires Per Terminal)
Wire Range
Cat. No. Qty Per Kit
250–1200 A
(6) 12–2/0 AWG Cu PDC6P20 3
(6) 12–2/0 AWG Cu PDC6P204 4
250–1200 A (12) 10–4 AWG Cu
PDC12P4 3
PDC12P44 4
e Not
for use with I-Line™ circuit breakers.
f Kit includes long terminal shield and cover, which adds 1.65 inches to standard lug with short terminal shield.
Class 0611, 612 / Refer to Catalogs
0611CT1001, 0612CT0101
DE3_p043.fm Page 43 Saturday, January 10, 2015 2:42 AM