DE3
CIRCUIT BREAKERS
01/15
DE3-23
PowerPact™ Circuit Breakers
H- and J-Frame Circuit Breakers
H-Frame 150 A and J-Frame 250 A Electronic Trip CSA/UL Current-Limitinga Circuit Breakers
(600 Vac) With Factory Sealed Trip Unitb Suitable for Reverse Connection g
Electronic T rip Unit
Sensor
Rating
Interrupting Rating (2nd Letter of Catalog Number)
Terminal
Type Function T rip Unit
D G Ja La Ra
$ Price
Catalogue
Numberc
Catalogue
Numberc
Catalogue
Numberc
Catalogue
Numberc
Catalogue
Numberc
600 Vac, 50/60 Hz, 3P
Micrologic
Standard
LI 3.2f
60 A
100 A
150 A
HDL36060U31X
HDL36100U31X
HDL36150U31X
HGL36060U31X
HGL36100U31X
HGL36150U31X
HJL36060U31X
HJL36100U31X
HJL36150U31X
HLL36060U31X
HLL36100U31X
HLL36150U31X
HRL36060U31X
HRL36100U31X
HRL36150U31X
AL150HDd
250 A JDL36250U31X JGL36250U31X JJL36250U31X JLL36250U31X JRL36250U31X AL250JDe
Micrologic
Standard
LSI 3.2Sf
60 A
100 A
150 A
HDL36060U33X
HDL36100U33X
HDL36150U33X
HGL36060U33X
HGL36100U33X
HGL36150U33X
HJL36060U33X
HJL36100U33X
HJL36150U33X
HLL36060U33X
HLL36100U33X
HLL36150U33X
HRL36060U33X
HRL36100U33X
HRL36150U33X
AL150HDd
250 A JDL36250U33X JGL36250U33X JJL36250U33X JLL36250U33X JRL36250U33X AL250JDe
Micrologic
Ammeter
LSI 5.2A
60 A
100 A
150 A
HDL36060U43X
HDL36100U43X
HDL36150U43X
HGL36060U43X
HGL36100U43X
HGL36150U43X
HJL36060U43X
HJL36100U43X
HJL36150U43X
HLL36060U43X
HLL36100U43X
HLL36150U43X
HRL36060U43X
HRL36100U43X
HRL36150U43X
AL150HDd
250 A JDL36250U43X JGL36250U43X JJL36250U43X JLL36250U43X JRL36250U43X AL250JDe
Micrologic
Energy
LSI 5.2E
60 A
100 A
150 A
HDL36060U53X
HDL36100U53X
HDL36150U53X
HGL36060U53X
HGL36100U53X
HGL36150U53X
HJL36060U53X
HJL36100U53X
HJL36150U53X
HLL36060U53X
HLL36100U53X
HLL36150U53X
HRL36060U53X
HRL36100U53X
HRL36150U53X
AL150HDd
250 A JDL36250U53X JGL36250U53X JJL36250U53X JLL36250U53X JRL36250U53X AL250JDe
Micrologic
Ammeter
LSIG 6.2A
60 A
100 A
150 A
HDL36060U44X
HDL36100U44X
HDL36150U44X
HGL36060U44X
HGL36100U44X
HGL36150U44X
HJL36060U44X
HJL36100U44X
HJL36150U44X
HLL36060U44X
HLL36100U44X
HLL36150U44X
HRL36060U44X
HRL36100U44X
HRL36150U44X
AL150HDd
250 A JDL36250U44X JGL36250U44X JJL36250U44X JLL36250U44X JRL36250U44X AL250JDe
Micrologic
Energy
LSIG 6.2E
60 A
100 A
150 A
HDL36060U54X
HDL36100U54X
HDL36150U54X
HGL36060U54X
HGL36100U54X
HGL36150U54X
HJL36060U54X
HJL36100U54X
HJL36150U54X
HLL36060U54X
HLL36100U54X
HLL36150U54X
HRL36060U54X
HRL36100U54X
HRL36150U54X
AL150HDd
250 A JDL36250U54X JGL36250U54X JJL36250U54X JLL36250U54X JRL36250U54X AL250JDe
a Circuit
breakers
with J, L, and R interrupting ratings are CSA/UL certified as current limiting.
b Refer to
catalogue 0611CT1001 for circuit breakers with field-interchangeable trip units
c For 100% rated circuit breakers, add a “C” in the 9th character place (for example, HGL36150CU31X, JGL36250CU43X)
100%
rated H- and J-frame circuit breakers have copper lugs and can only be used with copper wire.
d AL150HD wire
range is 14–3/0 A WG Al or Cu.
e AL250JD wire
range is 3/0 AWG–350 kcmil Al or Cu. For smaller wire range (4–4/0 AWG Al or Cu), replace the lug’s wire binding screws with the larger binding screws provided.
f 3P circuit breakers with this trip unit can be used for 2P applications.
g For applications requiring communications see page DE3-49
.
H-Frame
Micrologic™ Trip Unit
J-Frame
Micrologic™ Trip Unit
H- and J-Frame Termination Options
Termination Letter
A - I-Line (See Section 5)
HDL36015T
For factory-installed
termination, place termination
letter in the third block of the
circuit breaker catalog number.
Termination Letter
F = No Lugs (includes terminal nut kit on both ends)
L = Lugs both ends
M = Lugs ON end Terminal Nut Kit OFF end
P = Lugs OFF end Terminal Nut Kit ON end
N = Plug-in h
D=Drawouth
S = Rear Connected h
h For N and D details, refer to page DE3-45. For S details, refer to page DE3-41.
H- and J-Frame Interrupting Ratings
Voltage
Interrupting Rating
D G J L R
240 Vac 25 KA 65 kA 100 kA 125 kA 200 kA
480 Vac 18 kA 35 kA 65 kA 100 kA 200 kA
600 Vac 14 kA 18 kA 25 kA 50 kA 100 kA
rciMcigolo
E
2
.5
rI%
A
03
>
03>
011>
.9
2
9
.
3
9.
4
9.
59
.
1
89.
7
9
.
6
9
.
Ir
)
o
I
x
(
5.
1
2
5.2
3
4
01
8
6
5
dsI )rIx(
H-Frame Circuit Breaker with
Optional FDM and IFM Modules
Accessories ........................................Page DE3-39
Optional Lugs .......................................P age DE3-42
Dimensions .........................................P age DE3-55
Enclosures .........................................P age DE3-56
Class 611 / Refer to Catalog 0611CT1001
DE3_p023.fm Page 23 Saturday, January 10, 2015 2:25 AM
Vista de pagina 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 64 65

Comentarios a estos manuales

Sin comentarios