DE3
CIRCUIT BREAKERS
01/15
DE3-31
Motor Protectors
Motor Circuit Protectors and Motor Protector Circuit Breakers
Motor Circuit Protector
Motor Protector Circuit
Breaker
Motor Circuit Protectors
Mag-Gard™ Motor Circuit Protectors (MCP) are instantaneous-trip magnetic-only circuit breakers. They have a single
adjustment which simultaneously sets the magnetic trip level of each individual pole. Mag-Gard™ circuit breakers
comply with CEC/NEC requirements for providing motor circuit protection when installed as part of a UL Listed
combination controller having motor overload protection. Interrupting ratings are established for these CSA/UL
Recognized Components only when they are used in combination with motor starters with properly sized overload
relays and contactors.
All Mag-Gard circuit breakers will accept the same lugs and accessories as equivalent circuit breakers. Mag-Gard
circuit breakers are available with I-Line construction.d High-interruption (H) construction Mag-Gard circuit breakers
(LHL) are also available.
Magnetic Only 3 Pole, 600 Vac, 50/60 Hzd—Three Device Solutionsb
Ampere Rating
Trip
Unit
Adjustablea
Trip Range (A)
250 Vdc Multiplier Cat. No.
LAL 400
500–1000 A
750–1600 A
1000–2000 A
1125–2250 A
1250–2500 A
1500–3000 A
1750–3500 A
2000–4000 A
High = 1.2
Low = 1.4
LAL3640022M
LAL3640028M
LAL3640030M
LAL3640031M
LAL3640032M
LAL3640033M
LAL3640035M
LAL3640036M
For PowerPact L- and P-Frames, an instantaneous-only version of the electronic trip circuti breaker is also available for
motor circuit protection. These MCPs comply with CEC/NEC
®
requirements for providing short-circuit protection when
installed as part of a Listed combination controller having motor overload protection.
Magnetic Only 3 Pole, 600 Vac, 50/60 Hzd—Three Device Solutionsb
Sensor Rating
Trip
Unit
Adjustablea
Trip Range (A)
Interrupting Rating
G J L R
Cat. No. Cat. No. Cat. No. Cat. No.
PowerPact
L-Framed
400
1.3 M
500–1200% LGL36400M37X LJL36400M37X LLL36400M37X LRL36400M37X
600 500–1200% LGL36600M37X LJL36600M37X LLL36600M37X LRL36600M37X
PowerPact
PJL, PLLd
600 1200–10000 A — PJL36060M68 PLL34060M68 —
800 1200–10000 A — PJL36080M68 PLL34080M68 —
1000 1500–10000 A — PJL36100M69 PLL34100M69 —
1200 1800–10000 A — PJL36120M70 PLL34120M70 —
a CSA/UL magnetic trip tolerances are -20%/+30% from the nominal values shown.
b Three-device solutions
are the traditional solutionss: motor circuit protector plus motor starter plus overload relay.
c 250 Vdc ratings are available. No CSA/UL component recognition
d These electronic
magnetic only motor circuit protectors are available with I-Line constructions. Consult the factory.
Motor Protector Circuit Breakers
Motor protection circuit breakers provide built-in thermal and magnetic protection. They are used in two-device motor
feeder solutions to provide protection against short-circuits, overloads, and phase unbalance.
H-Frame (150 A), J-Frame (250 A) and L-Frame (600 A) Electronic Trip Motor Protector Circuit Breakers
(CSA/UL Ratings)—
Two Device Solutionse
Electronic
Trip Unit
Type
Frame
Sensor
Rating
Trip
Unit
Full Load
Amperes
Range
(FLA)
Isd (x FLA)
Interrupting Rating
G J L R
Cat. No. Cat. No. Cat. No. Cat. No.
Standardf
H-F rame
30
2.2 M
14–25 5-13 x FLA HGL36030M38X HJL36030M38X HLL36030M38X HRL36030M38X
50 14–42 5-13 x FLA HGL36050M38X HJL36050M38X HLL36050M38X HRL36050M38X
100 30–80 5-13 x FLA HGL36100M38X HJL36100M38X HLL36100M38X HRL36100M38X
150 58–130 5-13 x FLA HGL36150M38X HJL36150M38X HLL36150M38X HRL36150M38X
J-F rame 250 114–217 5-13 x FLA JGL36250M38X JJL36250M38X JLL36250M38X JRL36250M38X
L-F rame
400
2.3 M
190–348 5-13 x FLA LGL36400M38X LJL36400M38X LLL36400M38X LRL36400M38X
600 312–520 5-13 x FLA LGL36600M38X LJL36600M38X LLL36600M38X LRL36600M38X
e Two-device
solutions
(these electronic motor protector circuit breakers include short circuit and overload protection)
—1 electronic motor circuit protector with a Micrologic 2.2 M plus
—1 contactor
f The standard trip unit offers Class 5, 10 and 20 and phase unbalance or phase loss protection.
Accessories .........................................PageDE3-39
Optional Lugs .......................................P
ageDE3-42
Dimensions ............................. Pages DE3-54 and DE3-55
Enclosures..........................................P
ageDE3-56
Class 580, 585, 680, 685
DE3_p031.fm Page 31 Saturday, January 10, 2015 2:29 AM