DE3
CIRCUIT BREAKERS
01/15
DE3-40
PowerPact™ Circuit Breaker Accessories
Motor Operators and Rotary Handles
Motor Operators for H-, J-, and L-Frame Circuit Breakers
Description Rated Voltage
Factory
Installed
Cat. No. Suffix
Field--Installable Kit
H-Framea J-Frame L-Frame 600 A
Cat. No. Cat. No. Cat. No.
Standard motor for electrically-operated circuit
breakersb
AC
48-60 ML S29440 S31548 S432639
110-130 MA S29433 S31540 S432640
208-277
220-240
MD S29434 S31541 S432641
380-415 MF — — S432642
440-480 MH S29435 S31542 S432647
DC
24-30 MO S29436 S31543 S432643
48-60 MV S29437 S31544 S432644
110-130 MR S29438 S31545 S432645
250 MS S29439 S31546 S432646
Communicating motor for electrically-operated
circuit
break
ersc
AC 220-240 NC S429441 S431549 S432652
Locking device
Mounting hardware — — — S32649
Ronis lock — S41940 S41940 S41940
Profalux lock — S42888 S42888 S42888
Mounting hardware plus Ronis
lock
— S429449 S429449 —
Oper
ations counter — — — S32648
Adapter for I-Line circuit breaker — S37420 S37420 —
Spring-Charging Motors for Electrically-Operated P-Frame Circuit Breakers
Description Rated Voltage
Factory Installed P-Frame (For Field-replacement Only) Replacement Coils
Cat. No. Suffix Spring Charging Motor Cat. No. Opening/Closing Coil Cat. No.
Standard motor for electrically-
operated circuit breakers.
F actory-installed includes motor and
opening/closing coils.
AC
48 ML S47391 S33660
100-130 MA S47395 S33661
220-240 MC S47396 S33662
380-415 MF S47398 S33664
DC
24-30 MO S47390 S33659
48-60 MV S47391 S33660
110-130 MR S47392 S33661
200-250 MS S47393 S33662
Communicating motor mechanism for
electr
ically
operated circuit breakers.
F actory-installed includes motor
and opening/closing coils.
AC
48 NL S47391 S33034
100-130 NA S47395 S33035
220-240 NC S47396 S33036
380-415 NF S47398 S33038
DC
24-30 NO S47390 S33033
48-60 NV S47391 S33034
110-130 NR S47392 S33035
200-250 NS S47393 S33036
Rotary Operated Handles
Device Description
H- and J-Framea L-Frame P-Frame
Factory Installed
Cat. No. Suffix
Field Installable
Cat. No.
Factory Installed
Cat. No. Suffix
Field Installable
Cat. No.
Factory
Installed
Cat. No. Suffix
Direct Mounted
Standard black handle Handle only RD10 S29337 RD10 S32597 RD10
Standard black handle with
Two early-break and two early make switches — — — — RD16
One early-break switch RD12 S29337 +S29345 RD12 S32597 +S32605 —
Two early-make switches RD13 S29337 +S29346 RD13 S32597 +S29346 —
Red handle on yellow bezel
Handle only RD20 S29339 RD20 S32599 —
One early-break switch RD22 S29339 +S29345 RD22 S32599 +S32605 —
Two early-make switches RD23 S29339 +S29346 RD23 S32599 +S29346 —
MCC conversion accessory — S429341 — S32606 —
CNOMO conversion accessory — — — S32602 —
Door Mounted
Standard black handle Handle only RE10 S29338 RE10 S32598 RE10
Standard black handle
with:
Two early-break and two early make switches — — — — RE16
Two early make switches RE13 S29338 +S29346 RE13 S32598 +S29346 —
Red handle on yellow bezel Handle only RE20 S29340 RE20 S32600 —
Rotary Handle Replacement Kit — — — — S33875
Telescoping RT10 S29343 R T10 S32603 —
Accessories
K e y lock adapter — S429344 — S32604 —
K e y locks
Ronis 1351.500 — S41940 — S41940 —
Profalux KS5 B24 D4Z — S42888 — S42888 —
2 Ronis keyloc ks with 1 key — S41950 — S41950 —
2 Profalux keylocks with 1 key — S42878 — S42878 —
Indication Auxiliary Switch
One early-break switch — S29445 — S32605 —
Two early-make switches — S29346 — S29346 —
Door-Mounted
Handle
Direct-Mounted
handle
a Not available in H-frame 2P modules.
b Factory and
field-installed standard motor operators for H- and J-frame circuit breakers
require the SDE switch and SDE adapter (both included).
Factory and field-installed standard motor operators for L-frame circuit breakers require the
SDE switch (included).
c Installation requires
BSCM with NSX Cord. See page DE3-49 for ordering information.
Class 0611, 612 / Refer to Catalogs 0611CT1001, 0612CT0101
DE3_p040.fm Page 40 Saturday, January 10, 2015 2:32 AM